<snip>
"As I understand it... a type 1 or 6 SVC cannot SUSPEND, WAIT, or PAUSE
synchronously at all.  If they need to finish something later, they
schedule it and quit."

Not true. See note 8 in the link below...

https://www.ibm.com/docs/en/zos/2.1.0?topic=routines-programming-conventions-svc
</snip>

As Shmuel and Steve pointed out, it's all in the details. A type 1 or type 
6 SVC can issue SUSPEND, but noting that, in doing so, this is basically 
ending the SVC's processing. RESUME will occur within the user code 
(enabled and unlocked). 

A type 1 SVC must not release the local lock; a type 6 SVC must not 
enable.
A type 1 or type 6 SVC cannot suspend the SVC routine itself and have the 
SVC routine continue upon RESUME.

Peter
[email protected] 
     1-845-435-8390            8+295-8390


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to