=o

Then set the terminal to 3279 or similar. That should unlock the 3270 Model 
types. 

I’ve hit this once or twice also. 

Sent from my iPhone — small keyboarf, fat fungrs, stupd spell manglr. Expct 
mistaks 


> On Dec 23, 2021, at 5:44 PM, Jim Mooney 
> <[email protected]> wrote:
> 
> Hello list,
> 
> I have an ISPF Settings; Terminal Characteristics; Screen format mystery!
> 
> I have been searching but cannot find what causes DATA, & Max to be 'greyed 
> out' on the setting panel (=0). 
> I have a user who cannot set Screen format to 3 (Max). 
> I can choose any of the options, but this user cannot select anything except 
> '2' (Std).
> 
> With my userid I use the same settings
>   the same logon proc;
>   the same logmode -D4A32XX3, 
>   the same emulator settings - TN3270+; IBM-Dynamic; terminal 3279; custom 
> size: 60 rows & 160 cols.
> 
> ...and I am able to choose any Screen format, but the other user cannot 
> change from '2'. 
> 
> So I'm throwing this our for any ISPF experts out there.
> 
> Is there some ISPF parm conflict that disables all but the Std option?
> Or
> Is there something other than logmode and emulator that controls which Screen 
> Format options are available to each ISPF user?
> 
> Any ideas as to what I am missing?
> 
> Any input is appreciated. I am mystified. Also, I find nothing in the 
> archives about this.
> 
> Thx much!
> 
> Jim
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to