Looking on my system, I have an ADMDEFS dataset which contains the line:
 ADMMDFT APPCPG=1047
Which I believe resolves this issue.  The code page must match in both the QMF 
and DB2 subsystem definitions.

Hope this helps

On Tue, 9 Apr 2013 10:29:43 -0400, William Janulin <[email protected]> wrote:

>I am resending this as I just switched my subscription to gmail fro yahoo.
>If anyone has run into this situation, any information would be greatly
>appreciated. I am not sure what the easier solution would be on this, QMF
>versus DB2.
>
>Thank you in advance,
> Bill Janulin
>

----------------------------------------------------------------------