On 4/9/2013 7:03 PM, Kenneth Wilkerson wrote:
So now specifically to asynchronous exits. There are 3 ways to schedule
asynchronous exits that I know of, by STIMER(M), by SCHEDIRB and by the old,
SCHEDXIT. If there are other ways, please let me know.

There is at least one other - see the CIRB macro. Before HASP, operators on an OS/360 system had to issue an explicit START RDR command to read a job stream. I had a parameterized facility (define command, alter, delete by unit) that caused an unsolicited interrupt to a defined device to trigger the appropriate command, thus obviating the need for the operator to start the reader. For MVS I have a version with more flexibility - I can set an ATI in designated UCBs, and issue any command in response to an interrupt. This is handy for activating CRT terminals on a different floor (not all are defined to VTAM).

The MVS version does not use CIRB, nor does it use the Master Scheduler; instead it calls CVT0EF00 directly to schedule an IRB and IQE.

Gerhard Postpischil
Bradford, Vermont

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN