Yes, if you turn it on via

TRACE ST,MODE=ON

Jim Mulder z/OS Diagnosis, Design, Development, Test  IBM Corp. Poughkeepsie NY

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Paul Schuster
Sent: Thursday, July 28, 2022 3:15 PM
To: [email protected]
Subject: MODE trace entry

The manual z/OS: z/OS MVS Diagnosis: Tools and Service Aids GA32-0905-50 shows 
that a MODE trace entry will be generated for "a change into or out of 64-bit 
addressing mode".  Is a SAM64 instruction supposed to generate such a trace 
entry?  I am not seeing one when a SAM64 instruction is executed.

Thank you.

Paul

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN