The journal may be a bit small. It's only 25 cylinders. I'll expand it ASAP.
On Mon, Apr 15, 2013 at 8:57 AM, Staller, Allan <[email protected]> wrote: > You might to review "DFSMShsm in a multiple-image environment" in the > appropriate version of > DFSMShsm Implementation and Customization Guide. > > You have not indicated if you are running primary and secondary dfHSM tasks. > The guide specifically suggests this to prevent race conditions > during selected activities (migration, backup, recall, dump). > > If all is as indicated unless some *really really* serious activity > (migration, recall, backup) was going on, I would suggest a DASD error or > JOURNAL > dataset too small. Review the size and/or move the JOURNAL dataset to another > volume. > > BTW, I have been running in the same configuration (multi-HSM, base SYSPLEX) > since 2010 with no occurrence of this issue. > > Feel free to contact me off list if necessary... > > HTH, > > <snip> > last BACKVOL CDS was at 17:33:09 Saturday. The first ARC0026E message that I > can find in either SYSLOG is at 18:00:30 on Saturday, or about > 30 minutes later. > > On Mon, Apr 15, 2013 at 8:28 AM, Staller, Allan <[email protected]> > wrote: >> When was the last time you successfully ran a BACKVOL CDS command? >> >> <snip> >> *ARC0026E JOURNALING DISABLED DUE TO EOV ERROR ON 852 ARC0026E (CONT.) >> JOURNAL. MIGRATION, BACKUP, FRBACKUP, DUMP, TAPECOPY, ARC0026E (CONT.) >> TAPEREPL, RECYCLE, ARECOVER, AUDIT, AND EXPIREBV HELD. >> ARC0020I ****************************** >> >> This has happened before. This time, it appears that in addition to the >> above, that every job which issues a request to DFHSM via SVC-109, code >> x'18' went into a WAIT (SVC 1) on some ECB which was never POSTed. >> >> Has anybody seen this message before? How did you eliminate it? I have done >> what the book said: stop all DFHSM; rename old JOURNAL; all new JOURNAL data >> set;S DFHSM,EMERG=YES on one system; wait for it to come up; S DFHSM on >> second system. We have two systems sharing all the DFHSM data sets in a >> __basic__ sysplex (not parallel, we won't get a ICF engine). > </snip> > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN -- This is a test of the Emergency Broadcast System. If this had been an actual emergency, do you really think we'd stick around to tell you? Maranatha! <>< John McKown ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN