Look in etc/pagent_TTLS.conf there is a trace option under ttlsgroupaction. 
What do you have it set to?   This will get rid of some of them.

Then we suppress the messages using a/o from coming out on the syslog but they 
still come out on tcpip started task.

Hope this helps.

Shelia c 


-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Colin Paice
Sent: Sunday, October 9, 2022 11:09 AM
To: [email protected]
Subject: Can I supress BPXF024I ?

I'm trying to get a TENET/PAGENT trace out.  Typical output is

*BPXF024I (TCPIP) Oct  9 15:55:20 TTLS 83951653 : 15:55:20 TCPIP 057    *
EZD1286I TTLS Error GRPID: 0000001F ENVID: 00000017 CONNID: 0000005D
LOCAL: 10.1.1.2..2023 REMOTE: 10.1.0.2..42870 JOBNAME: TN3270 USERID:
TCPIP RULE: TN  RC:  402 Initial Handshake 0000000000000000
0000005011421D10 0000000000000000

*BPXF024I text: Explanation*

*The text is the contents of the user's write buffer at the time of the write 
request is displayed. Messages written to /dev/console by z/OS UNIX 
applications appear on the MVS™ console in this message.*


The BPXF024I is not needed...  it tells me what I already know. Is there a way 
of suppressing this?

Parts of TCPIP family write these to CTRACE - which is a faff.... start writer, 
start trace... connect to TCPIP.. stop writer, stop trace, use IPCS ctrace 
command.

Colin

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to