I am trying to migrate a simple CCW to tape test program from zVSE to
z/OS to help a customer. EXCP on z/OS is new to me. The program is
reading the label so I have BLP in the JCL and am running authorized and
within the correct initiator for BLP.
The OPEN and CLOSE using BLP works, but when I try a simple read, I get:
SYSTEM COMPLETION CODE=200 REASON CODE=00000313
Thoughts?
One think I am worried about is that I read into an area within the
program, not a GETMAINed area, but I compiled with NORENT
Some of the areas:
CCB001_ECB DS A(0)
CCB001 DS 0F IORB
CCB001_IOB DS 0F
CCB001_IOBFLAGS DC XL2'4300'
CCB001_IOBSENSE DC XL2'0000'
CCB001_IOBECBAD DC A(CCB001_ECB)
CCB001_IOBCSW DC A(0)
CCB001_IOBCSWFL DC XL2'0000'
CCB001_IOBRESDL DC H'00'
CCB001_IOBCCWAD DC A(CCW00101)
CCB001_IOBDCBAD DC A(SYS020)
DC 2A(0)
CCB001_IOBSEEK DC XL3'000000' MBB
CCB001_IOBSRCH DC XL5'0000000000' CCHHR
CCW00101 CCW CCWC_RD,DATA0102,CCWF_SLI,RECL0102
DATA0102 DS 0D
DC 1024XL32'00'
RECL0102 EQU *-DATA0102
Tony Thigpen
----------------------------------------------------------------------