Great, I will use the "128" method.
Thanks you all !

> Le 26 nov. 2022 à 18:47, Todd J. Gagle <[email protected]> a écrit :
> 
> Ed,
> 
> Thanks for correcting my typo.
> 
> Regarding the WLM information, the information that you mention is WLM 
> related as it is a detailed display from the WMSYSSUM command.
> As others have said, the values are displayed in seconds, but the source 
> value must be multiplied by 128 first to convert units.
> 
> It appears that you have found a bug. The "total source" value is getting 
> multiplied by 128 for a second time prior to computing the average.
> I will notify the SYSVIEW team about the bug.
> 
> Todd
> 
> ----------------------------------------------------------------------