Hi Listers

I was looking a Cobol code module developed and we ran in to a sco7 issue. I am 
not able to figure why this is abending.

Any help to fix is much appreciated. 

Here is the spool display i have captured. 

05 INP-VNDR-PACK-COST         PIC 9(9)V9(4).
05 WS-VNDR-PACK-COST         PIC S9(9)V9(4) COMP-3.

INP-VNDR-PACK-COST -00000000035.65
4CDD6EDCD6DCCD6CDEE46FFFFFFFFFFF4FF4444444444444444444444444444444444444
09570554907132036230000000000035B650000000000000000000000000000000000000
-----------------------------------------------------------------------
WS-VNDR-PACK-COST -0000000000000
4EE6EDCD6DCCD6CDEE46FFFFFFFFFFFFF444444444444444444444444444444444444444
062055490713203623000000000000000000000000000000000000000000000000000000
-----------------------------------------------------------------------

MOVE INP-VNDR-PACK-COST TO WS-VNDR-PACK-COST ---------------------------------> 
Here it is failing 


CEE3207S The system detected a data exception (System Completion Code=0
4CCCFFFFE4E884AAAA89488A88A8848488A848A889A89944EAAA894C99998A8994C9887F
03553207203850282354045353354010413105735739650D2823540364735396503645E0


Regards
Ron T


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to