We hit that as well last week on our test systems. UJ09197 has been marked PE, and APAR OA64137 has been opened.
Jim Mulder -----Original Message----- From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Ed Jaffe Sent: Sunday, January 15, 2023 12:22 PM To: [email protected] Subject: Beware IBM PTF UJ09197 (APAR OA63062) IBM-MAINaholics, Our HSM maintenance jobs failed this morning. The log was full of 0C4 abends pointing to offset +2B0 in TIOC LPA module IGC0009C. The failure appears related to TSO/E SEND command processing. PTF UJ09197 (APAR OA63062) updated IGC0009C yesterday morning via our weekly service APPLY. We backed out the PTF, re-IPLed the affected systems, re-ran the failing jobs, and now all is well... -- Phoenix Software International Edward E. Jaffe 831 Parkview Drive North El Segundo, CA 90245 https://www.phoenixsoftware.com/ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN