Sorry I am late to the game with this one.   First time I've had a breather to 
look
at IBM-MAIN all of February.

I suggest stopping / starting SDSF (which will stop/start SDSFAUX also) and 
that may
resolve the problem.   I ran into similar issues with both RMF and CMF when 
working
on z/OS 2.5.  The best indicator of this problem is to do "DA OJOB" and if you 
see
STCs, then recycling SDSF will resolve it.    If you have to recycle CMF or RMF 
for
any reason, you'll likely run into the same thing again and have to recycle SDSF
also.  

Change your automation to not start SDSF until after CMF tasks or RMF is started
at IPL time.  Making CMF/RMF a pre-req of SDSF should also remind someone
to recycle SDSF even if CMF/RMF is "forced" recycled without SDSF.   

Regards,

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS