Bill, Just a word of caution on the SMPPTSn spill datasets. Once you create them you have to keep them in sequence with no gaps. For example if you end up with SMPPTS1-4 (in addition to SMPPTS), and you later notice that SMPPTS2 is empty, don't just delete it. SMP/E stops looking for additional spill datasets once one is missing. So if you delete SMPPTS2, SMP/E won't even look at datasets 3 and 4.
Rex -----Original Message----- From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Bill Giannelli Sent: Wednesday, March 29, 2023 11:31 AM To: [email protected] Subject: [EXTERNAL] Re: concatenated SMPPTS datasets Hi David, Thank you for your response! That was easy! Thanks Bill On Wed, 29 Mar 2023 12:18:57 -0400, David Spiegel <[email protected]> wrote: >Hi Bill, >Create a DDDEF/Dataset for SMPPTS1, SMPPTS2 etc. >Be sure to add the DDDEFs to the Global, Target and DLIB Zones. > >Regards, >David > >On 2023-03-29 12:10, Bill Giannelli wrote: >> So, I have alot of maintenance to receive and am blowing out on SMPPTS. >> within SMPe can I concatenate a second dataset for SMPPTS in the DDDEF? >> thanks >> Bill >> >> --------------------------------------------------------------------- >> - For IBM-MAIN subscribe / signoff / archive access instructions, >> send email to [email protected] with the message: INFO >> IBM-MAIN > >---------------------------------------------------------------------- >For IBM-MAIN subscribe / signoff / archive access instructions, send >email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- The information contained in this message is confidential, protected from disclosure and may be legally privileged. If the reader of this message is not the intended recipient or an employee or agent responsible for delivering this message to the intended recipient, you are hereby notified that any disclosure, distribution, copying, or any action taken or action omitted in reliance on it, is strictly prohibited and may be unlawful. If you have received this communication in error, please notify us immediately by replying to this message and destroy the material in its entirety, whether in electronic or hard copy format. Thank you. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN