>>1) You could use IPOUPDTE also.

David,

AFAIK , IPOUPDTE can only work on PDS but does NOT work with sequential 
datasets.  OP hasn't specified if the input is a pds or sequential datasets. 
File-Manager handles both PDS and sequential files.

>>2) Does File manager do "intelligent changes" like ISPF Edit? (If Source 
>>String and Target String are different lengths, does the "line" beyond the 
>>change get shifted, or, if there multiple blanks, not necessarily)

The only restriction for file manager is

Data sets containing variable length records :  If a CHANGE command would 
result in an increase in the length of a variable length record, the change is 
not processed.

Here is the link to the documentation.
https://www.ibm.com/docs/en/file-manager-for-zos/14.1?topic=functions-fch-findchange

Thanks,
Kolusu


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to