1) Yes. The policy was written to a newly formatted CFRM couple dataset that 
I'm using as a policy syntax checker. This is the only policy in the dataset 
and the report was generated via the DATA TYPE(CFRM) REPORT(YES) command.
2) z/OS 2.5
3) No steplib.
4) No I haven't activated that policy yet. Might give it a go on Wednesday in 
our sysprog sandbox sysplex. 

Mark Jacobs 

Sent from ProtonMail, Swiss-based encrypted email.

GPG Public Key - 
https://api.protonmail.ch/pks/lookup?op=get&[email protected]


------- Original Message -------
On Friday, June 30th, 2023 at 1:22 PM, Bill Neiman <[email protected]> wrote:


> Mark,
> 
> I ran an IXCMIAPU job with your input, but could not recreate the behavior 
> you're seeing. The report section of the output reports the sizes as they 
> were input, with units of M. So now I have to ask the "Are you sure it's 
> plugged in?" questions. I apologize in advance for these:
> 
> o Are you looking at the report for the same administrative policy you 
> updated?
> 
> o On what release did you run the utility?
> 
> o Did you STEPLIB to some other version of IXCMIAPU?
> 
> o Did you start the new policy? If so, does a D XCF,STR,STRNAME=R901_GBP22 
> command show the same results as the utility?
> 
> Bill Neiman
> z/OS Parallel Sysplex development
> 
> 
> On Thu, 29 Jun 2023 12:48:59 +0000, Mark Jacobs [email protected] 
> wrote:
> 
> > 718 STRUCTURE NAME(R901_GBP22) INITSIZE(150M) SIZE(293M)
> > 719 PREFLIST(CFANB,CFBNB) REBUILDPERCENT(1) ALLOWAUTOALT(YES)
> > 
> > ADMINISTRATIVE DATA UTILITY: MESSAGES DATA TYPE = CFRM
> > ___________________________________________________________________________
> > 
> > IXC738I DEFINE POLICY (CFRMMJ) STATEMENT AT LINE 3 PASSED
> > VERIFICATION. THE POLICY CAN BE ADDED.
> > 
> > IXC739I DATA WAS CHANGED FOR COUPLE DATA TYPE CFRM
> > 
> > ---------------------------------------------------------------------------
> > 
> > ADMINISTRATIVE DATA UTILITY: REPORT DATA TYPE = CFRM
> > 
> > STRUCTURE NAME(R901_GBP22) SIZE(300032K)
> > INITSIZE(153600K)
> > ALLOWAUTOALT(YES)
> > REBUILDPERCENT(1)
> > PREFLIST(CFANB, CFBNB)
> > 
> > ______________________________________________________________________________
> > 
> > Thanks. Mark Jacobs
> > 
> > Sent from ProtonMail, Swiss-based encrypted email.
> > 
> > GPG Public Key - 
> > https://api.protonmail.ch/pks/lookup?op=get&[email protected]
> > 
> > ------- Original Message -------
> > On Thursday, June 29th, 2023 at 8:27 AM, Bill Neiman [email protected] 
> > wrote:
> > 
> > > Mark,
> > > 
> > > If you can supply an example of the input (CFRM policy) and output 
> > > (IXCMIAPU report) for one of the structures that provides output in units 
> > > of K instead of M, I'll take a look.
> > > 
> > > Bill Neiman
> > > IBM Parallel Sysplex Development
> 
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to