Hi,

Do you have SYS1.MODGEN?

Gerry

> On 25 Jul 2023, at 11:20, Sathish Kumar <[email protected]> wrote:
> 
> Hi,
> 
> Sure,  I don't have AMODGEN Marco library. So how we can proceed?
> 
> Thanks,
> 
> 
>> On Tue, 25 Jul, 2023, 12:41 am Steve Thompson, <[email protected]> wrote:
>> 
>> What Allen said.
>> 
>> And make sure you follow what the install doc says for
>> Connect:Direct, as well as any HOLD ACTIONs: do the actions
>> before BYPASS.
>> 
>> Steve Thompson
>> 
>>> On 7/24/2023 1:44 PM, Allan Staller wrote:
>>> Classification: Confidential
>>> 
>>> Most likley it is a missing library in the SYSLIB concatenation.
>>> 
>>> 1) Check the assembly listing for "macro not found" messages
>>> 2) locate the macro
>>> 3) Using the SMPE dialogs, adjust the SYSLIB DDDEF to include the
>> missing macro library(ies)
>>> 
>>> HTH,
>>> 
>>> -----Original Message-----
>>> From: IBM Mainframe Discussion List <[email protected]> On
>> Behalf Of Sathish Kumar
>>> Sent: Monday, July 24, 2023 12:41 PM
>>> To: [email protected]
>>> Subject: Apply job failed GIM240001E for connect direct 6.2
>>> 
>>> [CAUTION: This Email is from outside the Organization. Unless you trust
>> the sender, Don’t click links or open attachments as it may be a Phishing
>> email, which can steal your Information and compromise your Computer.]
>>> 
>>> Hi All,
>>> 
>>> While apply the usermod I get below error for connect direct.
>>> 
>>> GIM240001E ** Assembler processing for sysmid LDIACRJ failed for module
>> DGAXACRJ in the SDGASAMP library.  The return code 12 Exceeded for the
>> allowable value.
>>> 
>>> ASMA057E undefined operation code.
>>> 
>>> Lot of ASM* Errors messages in sysprint.
>>> 
>>> Please advise on this.
>>> 
>>> Thanks.
>>> 
>>> ----------------------------------------------------------------------
>>> For IBM-MAIN subscribe / signoff / archive access instructions, send
>> email to [email protected] with the message: INFO IBM-MAIN
>>> ::DISCLAIMER::
>>> ________________________________
>>> The contents of this e-mail and any attachment(s) are confidential and
>> intended for the named recipient(s) only. E-mail transmission is not
>> guaranteed to be secure or error-free as information could be intercepted,
>> corrupted, lost, destroyed, arrive late or incomplete, or may contain
>> viruses in transmission. The e mail and its contents (with or without
>> referred errors) shall therefore not attach any liability on the originator
>> or HCL or its affiliates. Views or opinions, if any, presented in this
>> email are solely those of the author and may not necessarily reflect the
>> views or opinions of HCL or its affiliates. Any form of reproduction,
>> dissemination, copying, disclosure, modification, distribution and / or
>> publication of this message without the prior written consent of authorized
>> representative of HCL is strictly prohibited. If you have received this
>> email in error please delete it and notify the sender immediately. Before
>> opening any email and/or attachments, please check them for viruses and
>> other defects.
>>> ________________________________
>>> 
>>> ----------------------------------------------------------------------
>>> For IBM-MAIN subscribe / signoff / archive access instructions,
>>> send email to [email protected] with the message: INFO IBM-MAIN
>> 
>> 
>> ----------------------------------------------------------------------
>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> send email to [email protected] with the message: INFO IBM-MAIN
>> 
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to