HI Mark, 
Looks like it will require a HW/SW update after all.  I created a deck after 
making the OS Config changes, and at the top of the deck is an ID statement, 
with one of the parameters being "TOK" with a pile of numbers/date/time and so 
forth.  It's completely different from the original IOCP deck.  I guess every 
time any Production IODF is created, a new token goes with it.  
 
Gord Neill
Senior IT Consultant - zSystems and LinuxONE
GlassHouse Systems Inc.
Phone: 416-229-2950 x306
Mobile: 416-347-8454
www.ghsystems.com 

Should you wish me to remove your name from my email contact list, please reply 
to this email and indicate so in the subject line. Thank you.


-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Mark Zelden
Sent: Wednesday, August 23, 2023 7:37 PM
To: [email protected]
Subject: Re: Changing a LIBRARY-ID in the OSCONFIG of HCD

On Wed, 23 Aug 2023 13:21:26 +0000, Gord Neill <[email protected]> wrote:

>Hello List,
>Working with a customer has a TS7760 installed, and they want to connect a new 
>TS7770 to the same CPU for testing/GRID work on a sandbox LPAR.  They have 
>Channel/CU/UADD definitions in their IOCP for an old box (TS7740) that is no 
>longer there, but to get the TS7770 in the same GRID as the TS7760 using these 
>old definitions, they need to update the LIBRARY-ID of this old TS7740 box to 
>match the LIBRARY-ID of the existing TS7760.
>
>The question:  In updating the LIBRARY-ID in the OSCONFIG for the sandbox LPAR 
>and building the Production IODF, will there be a new hardware token 
>generated, i.e. this new IODF would have to rolled out to all LPARs to keep 
>the hardware tokens in sync for future dynamic activates, or is this only a 
>software update with no effect on the existing hardware token?
>
>BTW, is there anywhere in HCD that you can see the generated token?
>

It should be software / "MVS" only.  A good way to check is to create an IOCP 
deck. 
If you did you wouldn't see any of that information in there.  

It think the answer to the 2nd question is "no".  

Regards,

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS ITIL v3 
Foundation Certified mailto:[email protected] Mark's MVS Utilities: 
http://www.mzelden.com/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to