SDSF calls the BPXEKDA service to get this information and this only returns truncated command information. When the PS command was originally written OMVS segments were not commonplace and the design goal was to provide the data without being dubbed (which would have been required for calling something like BPX1GTH).
BPXEKDA is used by the operator command responses which probably explains the truncation length. We are fully aware of the limitations on this implementation and have an existing RFE to provide more information. Rob Scott Rocket Software Sent from Outlook for Android<https://aka.ms/AAb9ysg> ________________________________ From: IBM Mainframe Discussion List <[email protected]> on behalf of Paul Gilmartin <[email protected]> Sent: Saturday, February 3, 2024 5:37:20 AM To: [email protected] <[email protected]> Subject: Re: SDSF PS Command column EXTERNAL EMAIL On Fri, 2 Feb 2024 15:55:26 -0600, Mark Zelden wrote: >On Fri, 2 Feb 2024 19:30:39 +0000, Frank Swarbrick wrote: > >>Is there any way to get more than the first 40 characters of the associated >>command line for a job in the PS screen? > >Limited to 40 characters. regardless of what you put in arrange. (someone >can open an enhancement request) > No, that should be a Support request Some defects are simply too wrong to be subjects for enhancement. Regardless of documentation. -- gil ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ================================ Rocket Software, Inc. and subsidiaries ? 77 Fourth Avenue, Waltham MA 02451 ? Main Office Toll Free Number: +1 855.577.4323 Contact Customer Support: https://my.rocketsoftware.com/RocketCommunity/RCEmailSupport Unsubscribe from Marketing Messages/Manage Your Subscription Preferences - http://www.rocketsoftware.com/manage-your-email-preferences Privacy Policy - http://www.rocketsoftware.com/company/legal/privacy-policy ================================ This communication and any attachments may contain confidential information of Rocket Software, Inc. All unauthorized use, disclosure or distribution is prohibited. If you are not the intended recipient, please notify Rocket Software immediately and destroy all copies of this communication. Thank you. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN