G'Day, I have a problem with a backup tape. HSM was performing its scheduled incremental backup when a problem occurred with the drive. The tech. needed the drive to fix it so I had to cancel HSM, however I stopped all activity, also, since the window for PRIMARY SPACE MANAGEMENT had been passed the backup function was not running. However, when I started up HSM I noticed the following message : ARC0378I TTOC RECORD AND TAPE MEDIA CONTENTS ARE INCONSISTENT ON TAPE VOLUME ZQ0813 I tried to recycle the tape but I got the mesage : ARC0830I RECYCLE COMMAND PROCESSING STARTING ARC0838I VOLUME ZQ0813 FULL=YES, PERCENT VALID=006, VOLUME TYPE=DAILY(06), FAILE FAILED CREATION=YES ARC0445I VOLUME ZQ0813 CANNOT BE RECYCLED, REASON= 0008, EXPLANATION: TTOC RECOR ARC0847I RECYCLE INPUT VOLUMES FREED=0000, OUTPUT VOLUMES USED=0000 ARC0831I RECYCLE COMMAND PROCESSING ENDING A colleague recommeneded to fix the ARC0378I problem I should run an AUDIT: HSEND AUDIT MEDIACONTROLS VOLUMES(ZQ0813) NOFIX My question is would this correct the problem and what is the difference between NOFIX and FIX parms? Thanks.