Classification: Confidential

The most likely reason is the DATACLAS(? Possibly MGMTCLAS)  ACS Routine. This  
is where partial space release is specified.
It is possible, but un likely that dfHSM is doing the partial space release. 
HSM would be honoring the "dictates" of the DATACLAS.

HTH,


-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Bob 
Bridges
Sent: Wednesday, February 21, 2024 11:45 AM
To: [email protected]
Subject: Something keeps releasing space on a large (annual) DS

[CAUTION: This Email is from outside the Organization. Unless you trust the 
sender, Don’t click links or open attachments as it may be a Phishing email, 
which can steal your Information and compromise your Computer.]

I'm not a sysprog (just a security geek), but I can at least allocate datasets, 
and at the start of this year it fell to me to allocate a new dataset in which 
are logged all changes made in the security system.  Past year's log are in the 
12000-track range, so I started with a smaller allocation while I took the time 
to talk to our sysprog about space requirements.  It's populated from a daily 
production job, by the way.

When I re-allocated it, on his advice I tried a multi-volume and extended 
allocation (PS-E).  Almost immediately the job started bombing, claiming that 
the first four volumes it tried didn't have the necessary space to add an 
extension.  The sysprog is puzzled - says it should have looked in volumes that 
DO have the space, not the ones that don't.

Second attempt (I don't count the temporary smaller allocation) I kept PS-E but 
dropped the multi-volume requirement.  I've never done one of those anyway, and 
don't trust 'em.  The system promptly dropped the extra tracks I allocated, and 
a day or two later the job started bombing with a B37-04.

Third attempt: Forget PS-E (I'm unfamiliar with that too) and just used 
SPACE=(TRK,(9000,1000)).  That seemed to work for a whole week, but I just 
noticed that something, somewhere, has released extra space AGAIN; 3.4 tells me 
it's now 1960 tracks and 83%.  The job isn’t bombing yet; some time later in 
the year I'm guessing it's going to.

Pardon my frustration: WHAT THE HECK IS GOING ON?  Why does it keep releasing 
space although I never specified RLSE?  The sysprog doesn't know either - but 
he's an external contractor who just took over the system a few months ago and 
if it's something simple he may not be aware yet of ... I dunno, something in 
SMS maybe?

Some wrinkles that may or may not be relevant:

1) The dataset is written using a REXX exec that calculates the DSN by 
reference to the current year.  This relieves folks from having to update the 
JCL every year, but maybe something about the way the exec does the allocate is 
causing the problem?  I'm guessing not, because as far as I now this job has 
run correctly for years.  But just in case:

  "ALLOC DDN(CHG$$OT) DSN('<dsn>') MOD CATALOG REUSE",
      "SPACE(300,30) CYLINDERS RECFM(V,B) LRECL(304) BLKSIZE(27998)"

2) I don't know anything about SMS, but could something there be releasing 
space?

3) What IS extended PS, anyway?  I'm told it allows more than 16 extents, but 
a) how many more? And b) how else is it different?

4) I allocated the dataset each time using not batch JCL but 3.2 ... expecting 
there's no difference.

---
Bob Bridges, [email protected], cell 336 382-7313

/* Law #6 of combat operations:  If it's stupid but it works, it isn't stupid. 
*/

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN
::DISCLAIMER::
________________________________
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
________________________________

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN