Just a thought, but 30's compress quite well also.
Michael
At 07:18 AM 4/17/2024, rpinion865 wrote:
Also, you will need this for SMF compression.
ISRBROBA PINIONR.BAS.PARMLIB(SMFPRM00) - 01.12 Line 0000000000 Col 00
Command ===> Scroll ===>
******************************** Top of Data ****************************
INTVAL(30) /* SMF GLOBAL RECORDING INTERVAL */
ACTIVE /* ACTIVE SMF RECORDING */
RECORDING(LOGSTREAM)
LSNAME(IFASMF.&SYSNAME..CICS,TYPE(110),COMPRESS)
LSNAME(IFASMF.&SYSNAME..DB2,TYPE(100:102),COMPRESS)
LSNAME(IFASMF.&SYSNAME..SCRT,TYPE(70,89),COMPRESS)
LSNAME(IFASMF.&SYSNAME..DEFAULT,TYPE(0:99,103:109,111:2047),
COMPRESS)
Sent with Proton Mail secure email.
On Wednesday, April 17th, 2024 at 8:08 AM,
Jousma, David <[email protected]> wrote:
> Thank-you very much for this! I suspect this
is the route we will have to take. To answer
your other question, yes, ZEDC is a chargeable
feature (although very inexpensive) and is turned on in IFAPRD00.
>
> Dave Jousma
> Vice President | Director, Technology Engineering
>
>
>
> From: IBM Mainframe Discussion List
[email protected] on behalf of
rpinion865 [email protected]
>
> Date: Tuesday, April 16, 2024 at 3:41â¯PM
> To: [email protected] [email protected]
>
> Subject: Re: Anyone exploiting ZEDC?
> FWIW, here is a snippet of the SMS ACS DC
code that we were using for zEDC. /* DEFINE
extra data sets to receive zEDC compression /
/--------------------------------------------------------------------/
FILTLIST COMP_DSN INCLUDE(CCM.âCCM%%%%.âFDR.â*,
>
>
> FWIW, here is a snippet of the SMS ACS DC code that we were using for zEDC.
>
>
>
> / DEFINE extra data sets to receive zEDC compression /
>
>
>
> /--------------------------------------------------------------------/
>
>
>
>
>
>
>
> FILTLIST COMP_DSN INCLUDE(CCM.CCM%%%%.FDR.,
>
> RMS.PROD.MSA.BKUP.,
>
> LOGR.IFASMF.,
>
> DB2%.ARCHLOG%.)
>
>
>
> - - - - - - - - - - - - - - - - - - 46 Line(s) not Displ
>
>
>
> /* RULES FOR DISK zEDC HW data compression /
>
>
>
> /--------------------------------------------------------------------*/
>
>
>
> WHEN (&DSN = &COMP_DSN) SET &DATACLAS='COMP'
>
> WHEN (&DSTYPE = 'GDS' && &SIZE > 270MB)
>
>
> SET &DATACLAS='COMP'
>
> WHEN (&PGM = 'ADRDSSU' && &SIZE > 55MB)
>
>
> SET &DATACLAS='COMP'
>
>
>
>
>
>
>
>
>
> This e-mail transmission contains information
that is confidential and may be privileged. It
is intended only for the addressee(s) named
above. If you receive this e-mail in error,
please do not read, copy or disseminate it in
any manner. If you are not the intended
recipient, any disclosure, copying,
distribution or use of the contents of this
information is prohibited. Please reply to the
message immediately by informing the sender
that the message was misdirected. After
replying, please erase it from your computer
system. Your assistance in correcting this error is appreciated.
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------