On Sat, 4 May 2024 08:57:52 -0500 Giliad Wilf <000000d50942efa9-dmarc-requ...@listserv.ua.edu> wrote:
:>On Sat, 4 May 2024 03:55:45 -0500, Giliad Wilf <gili...@yahoo.com> wrote: :>>On Mon, 22 Apr 2024 15:17:47 +0300, Binyamin Dissen <bdis...@dissensoftware.com> wrote: :>>>Saw the example, tried with and without quotes. No luck. . :>>Sorry, I only saw this post yesterday. :>>I've forced IPL to issue msg. IEA101A by changing IMSI char. from M to T in IPL parameter. :>>First, I've specified SYSP=DW, because our LOADxx specifies 'SYSPARM DW'. :>>The list of SYSP suffixes must be completed on a single response and can't be split... . :>Much to my embarrassment I did not test the same case. :>After deliberately messing with the PROG list, replacing a comma with a period, I could not respecify the PROG list split into two and had to respecify the entire list in a single response...[sigh]. :>Fortunately enough, respecifying the entire list did not exceed 80 chars. (the maximum)... To my luck there were various PROG= entries that didn't exist, so finally I made a working list that worked in one reply. -- Binyamin Dissen <bdis...@dissensoftware.com> http://www.dissensoftware.com Director, Dissen Software, Bar & Grill - Israel ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN