Hello, Thanks to Binyamin, the compiler option to avoid such check is SSRANGE(ZLEN). This is working quite well with COBOL 6.4.
Thanks all Best regards Prasanth Sukumaran Nair ITERGO Informationstechnologie GmbH Development Tools and Application Security Referent Überseering 45 22297 Hamburg Phone +49 40 6376-2402 [email protected] Chairman of the Supervisory Board: Robin Johnson Executive Management: Mario Krause (Chairman), Michael Liebe, Tony Cameron McCarthy, Caroline Meister, Jens Parthe, Rui Valente Registered Office: Düsseldorf, Commercial Register: District Court Düsseldorf, HRB 37996 -----Ursprüngliche Nachricht----- Von: IBM Mainframe Discussion List <[email protected]> Im Auftrag von Peter Van Dyke Gesendet: Mittwoch, 31. Juli 2024 03:40 An: [email protected] Betreff: [EXTERN] Re: COBOL v6.4 INVDATA problem Just to add to my previous response, as suggested by Binyamin you need to look at the setting for the SSRANGE compiler option, which can generate code to check for invalid reference-modification expressions for substrings. Peter Van Dyke On Wed, 31 Jul 2024 at 08:34, Peter Van Dyke <[email protected]> wrote: > Hi, > > The INVDATA compiler option is related to the processing of invalid > numeric data in USAGE DISPLAY and USAGE PACKED-DECIMAL data items. The > tests in question involve invalid substrings so I don't believe they > would be relevant to the INVDATA option. > > Peter Van Dyke > > On Tue, 30 Jul 2024 at 22:32, Steve Thompson <[email protected]> wrote: > >> Hi Prasanth: >> Because of working with people who came to COBOL after using Object >> Oriented languages, I think you need to be aware of the following so >> that you correctly state problems: >> >> COBOL is a procedural language. Programs compiled by a COBOL compiler >> do not throw errors, ABENDs, protection exceptions, etc. >> OO languages do this. Yes COBOL 6.x does have some OO support but not >> like you may want. >> >> Most of the programs that run in the z/OS environment are not Object >> oriented, so they issue condition codes (CC) or Messages, or they >> ABEND (ABnormal END). >> >> Therefore, COBOL issues messages and gives Condition/return codes or >> it ABENDs. >> >> If you have the latest PTFs on your COBOL 4.2 (?) system, you can >> turn on an option (if I remember this correctly) and it will flag >> statements that will not be supported by COBOL 5(?) and later, or >> will not be treated the same. >> >> I have forgotten the option for this. But I think it is specified in >> the COBOL 6.x Migration Guide. >> >> So that may be of help as you migrate from 4 to 6.x. >> >> In the case you have below, that option should have caught that. >> But, the current COBOL compiler you are using detected the error and >> flagged it. >> >> Hope this helps you. >> >> >> Steve Thompson >> >> >> >> On 7/30/2024 9:03 AM, Prasanth S wrote: >> > Hi, >> > >> > We are planning to switch from COBOL V4 to V6.4 in due time. >> > We have found that the INVDATA option of COBOL V6.4 mimics the V4 >> behaviour and plan to use it when 6.4 compiled modules throw error >> when invalid data is present. >> > One such test was to check the 0 length and negative length moves >> > as in >> the following: >> > >> > DISPLAY 'Substrings with a length shorter than 1' >> > >> > DISPLAY "Positive Lange" >> > >> > MOVE +5 TO ZW-START >> > >> > MOVE +4 TO ZW-LENGTH >> > >> > DISPLAY ZW-TEXT(ZW-START:ZW-LENGTH) >> > >> > DISPLAY "Lange Null" >> > >> > MOVE +5 TO ZW-START >> > >> > MOVE +0 TO ZW-LENGTH >> > >> > DISPLAY ZW-TEXT(ZW-START:ZW-LENGTH) >> > >> > DISPLAY "Negative Lange" >> > >> > MOVE +5 TO ZW-START >> > >> > MOVE -1 TO ZW-LENGTH >> > >> > DISPLAY ZW-TEXT(ZW-START:ZW-LENGTH) >> > >> > DISPLAY "The End" >> > >> > STOP RUN. >> > >> > This code ran ok when compiled with COBOL V4 but did not work well >> > with >> COBOL V6.4 with INVDATA option. >> > The error thrown was: >> > >> > IGZ0073S A non-positive reference modification length value of 0 on >> line 000052 >> > >> > ZW-TEXT. >> > >> > If any of you have already experienced this and have an explanation >> > or >> a solution, I would be grateful if you could share that. >> > >> > Thanks in advance, >> > >> > Best regards >> > Prasanth Sukumaran Nair >> > >> > ITERGO Informationstechnologie GmbH Development Tools and >> > Application Security Referent Überseering 45 >> > 22297 Hamburg >> > >> > Phone +49 40 6376-2402 >> > [email protected] >> > >> > Chairman of the Supervisory Board: Robin Johnson Executive >> > Management: Mario Krause (Chairman), Michael Liebe, Tony Cameron >> > McCarthy, Caroline Meister, Jens Parthe, >> Rui Valente >> > Registered Office: Düsseldorf, Commercial Register: District Court >> Düsseldorf, HRB 37996 >> > >> > ------------------------------------------------------------------- >> > --- For IBM-MAIN subscribe / signoff / archive access instructions, >> > send email to [email protected] with the message: INFO >> > IBM-MAIN >> >> --------------------------------------------------------------------- >> - For IBM-MAIN subscribe / signoff / archive access instructions, >> send email to [email protected] with the message: INFO >> IBM-MAIN >> > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN