Note that overriding the RECFM to U does not work for SMS compressed
datasets unless they were created as RECFM=U.
Michael
At 09:01 PM 8/18/2024, Paul Gilmartin wrote:
On Sun, 18 Aug 2024 19:26:56 -0500, Jason Cai wrote:
At times, to meet such a requirement, I have overridden the input
data set to DCB=RECFM=U.
o That requires that I control both ends of the process.
o That preserves both BDWs and RDWs.
o I believe that is the technique SMP/E RECEIVE FROMNETWORK
uses to package IEBCOPY unloaded libraries.
Why are you considering changing from a process that provably
works to an unproven one?
-- o It's a shame that LOCSITE RDW isn't reversible.
o It's a shame that LOCSITE RDW isn't compatible with FILEDATA=RECORD.
Conway's law.
gil
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN