Date: Wed, 2 Oct 2024 16:45:10 -0500
From: Wayne Driscoll <[email protected]>
Subject: Re: Question on HLASM - B to a DROP statement!?!
Note that in my case the assembler made it obvious that there is a slack
byte at X'000D' so a branch to MYTAG would result in an 0C1.
Branching to an odd address generates a specification exception, not an
operation exception. I would expect a S0C6, not a S0C1.
--
------------------------------------------------------------------------
*G. Tom Russell* Cell: +1 (416) 434-1706
------------------------------------------------------------------------
“Stay calm. Be brave. Wait for the signs” — Jasper FriendlyBear
“… and remember to leave good news alone.” — Gracie HeavyHand
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN