Im guessing you have tried COPY
With Process(SYS1) and exclude VVDS

Sent from my iPhone

No one said I could type with one thumb 

> On Nov 15, 2024, at 16:35, Radoslaw Skorupka 
> <[email protected]> wrote:
> 
> I'm trying to CONSOLIDATE and (in later step) DEFRAG datasets on some volume.
> It is *not* SYSRES, however it contains copy of system libraries, i.e. 
> SYS1.HELP or SISPLOAD, etc.
> Unfortunately most of the datasets is omitted with the message "DATA SET 
> dsname IN USER AND WAS NOT MOVED"
> I stopped LLA and issued SETPROG LNKLST,UNALLOCATE. Neither LLA nor XCFAS are 
> keeping the enqueue.
> However it seems, the DSS "knows better" and refuse to touch those datasets.
> Again - it is not a SYSRES. Those datasets are even not cataloged.
> 
> Q: How to circumvent the problem?
> 
> The only idea I imagine is to use some tool (which one???) to rename SYS1.* 
> to SYS2.* then do the DSS work, then rename it back.
> 
> Any clue?
> 
> --
> Radoslaw Skorupka
> Lodz, Poland
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,