On Fri, 15 Nov 2024 23:27:50 +0100, Radoslaw Skorupka wrote:
>W dniu 15.11.2024 o 22:40, Baessler, Derek pisze:
> ...
>IMHO the simplest solution is to fix the report dataset or create custom
>translation table for FTP to change X'00' to X'20' (as well as X'40' to
>X'20').
>
I suffered a similar problem with Linkage Editor SYSPRINT. IBM fixed
it by A{AR.
I conjecture that the defective code had cleared a buffer with XC then
populated it sparsely. And that the output was tested on a 3211-like
printer that tolerated the flaw.
Such things reinforce my objection to Postel's Robustness Principle,
which assisted in the escape of the defect to the field.
--
gil
----------------------------------------------------------------------