Binyamin,

Thanks for your cryptic hint. On its own not very helpful, but I do know about 
how to change the TIOT size at IPL.

I am well aware that the size of the TIOT affects the number of allocations 
that can be performed.  But I don't understand how these two limits (TIOT size 
and DYNAMNBR) affect the limit on the number of allocations I can have. 

I suspect there is a crucial piece of documentation missing, but I have never 
worked it out.
Lennie

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Binyamin Dissen
Sent: 04 December 2024 10:48
To: [email protected]
Subject: Re: DYNAMNBR

ALLOC** TIOT SIZE

On Wed, 4 Dec 2024 09:09:10 +0000 Lennie Bradshaw <[email protected]> 
wrote:

:>Greetings all,
:>The JCL Reference manual (SA23-1385-60) states that the DYNAMNBR parameter 
can specify a value that is added to the number of existing DD statements for a 
job step to produce an upper limit on the number of DD statements that may be 
allocated. It also talks about the size of the TIOT and the number of DD 
statements it can support and mentions various caveats about the number of 
UNITs used, passed data sets, and so on. (It does *not* discuss the 
"permanently allocated" attribute.)

:>However it states that the default for DYNAMNBR is zero (0). This would mean 
that if no DYNAMNBR is specified that the value used is zero.

:>However, this would mean that unless existing DD statements were closed or 
freed up in some way, then the number of DD statements I could dynamically 
allocate would be, again zero.

:>Yet I can use dynamic allocation without specifying DYNAMNBR. How is this 
working? Is the JCL Reference wrong? Or is there some piece of this puzzle that 
is missing?

:>I have looked in several other manuals including the Init and Tuning guide 
and the Auth Assembler reference, but cannot see how this is working.

--
Binyamin Dissen <[email protected]> http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to