How did you get the DUCT address? On Mon, 27 Jan 2025 13:37:00 +0000 Joseph Reichman <[email protected]> wrote:
:>Its time to FESS up I got this running under TESTAUTH trying to implement TRAP2 :> :>I moved the address of the trap control block at X2C bit 0 of this address was zero at bit 31 I turned that on to enable trap :>I was in key zero supervisor state :> :>Does it matter that the TCB it was running under had a TCBPFK of x80 :> :>Dont expect too many people to know as its not something done everyday :> :>But Binyamin seems to have run across almost everything :> :>Thanks :> :>Get Outlook for iOS<https://aka.ms/o0ukef> :>________________________________ :>From: IBM Mainframe Discussion List <[email protected]> on behalf of Binyamin Dissen <[email protected]> :>Sent: Monday, January 27, 2025 8:31:09 AM :>To: [email protected] <[email protected]> :>Subject: Re: Explanation of TCBPFK :> :>Strangely enough, PIC-5 was not wrapped into 0C4. :> :>Of course, PIC-5 cannot occur with DAT (unless, I guess, the page or segment :>table entry points to non-existant storage). :> :> :>On Mon, 27 Jan 2025 11:33:42 +0000 Seymour J Metz <[email protected]> wrote: :> :>:>To clarify, an S0C4 can have any of the interrupt codes 4, 10, 11, 2B, 38, 39, 3A, 3B, and only 4 can relate to the protection key. :>:> :>:>Does anybody have any statistics on the relative frequencies of S0C4 IC 4 for key mismatch, fetch protect, low storage protect, page protect and segment protect? :>:> :>:>-- :>:>Shmuel (Seymour J.) Metz :>:>http://mason.gmu.edu/~smetz3 :>:>??? ?????????? ??? :>:>?????? ??????????? ???? ?????????? :>:> :>:> :>:> :>:>________________________________________ :>:>From: IBM Mainframe Discussion List <[email protected]> on behalf of Seymour J Metz <[email protected]> :>:>Sent: Sunday, January 26, 2025 10:07 PM :>:>To: [email protected] :>:>Subject: Re: Explanation of TCBPFK :>:> :>:>External Message: Use Caution :>:> :>:> :>:>Way back in the dawn of history, IBM did something that appalled me, and you are the latest victim. While for other S0Cx ABENDs the last digit identifies the program interrupt code, for S0C4 there are multiple possible interrupt code, and 0004 is not the most common. Most likely you got a 0010 or 0011, or the Z equivalent. -- Binyamin Dissen <[email protected]> http://www.dissensoftware.com Director, Dissen Software, Bar & Grill - Israel ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN