Hello Rexx

IEE174I 08.44.33 DISPLAY M 180

DEVICE 00802   STATUS=OFFLINE

CHP                   2C

ENTRY LINK ADDRESS    ..

DEST LINK ADDRESS     0D

PATH ONLINE           Y

CHP PHYSICALLY ONLINE Y

PATH OPERATIONAL      N

PATHS NOT VALIDATED

On Thu, 20 Feb 2025, 21:05 Pommier, Rex, <
[email protected]> wrote:

> If you do a D M=DEV(802) on the console what do you see?  Does it show the
> path online?  The CHPID?
>
> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On Behalf
> Of Jake Anderson
> Sent: Thursday, February 20, 2025 10:38 AM
> To: [email protected]
> Subject: [EXTERNAL] OSA-C Console device 3277
>
> Hello
>
> We have console defined for 800,14 defined under IODF and under HMC - OSA
> advanced facility I can see the device 802 under the OSA chpid 0110.
> But when I vary on these device from zOS it gives me a mesaage as "unit
> 802 not bought online No paths physically available".
>
> I am i missing anything here or I need to check something?
>
> Jake
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to