Partial resolution.

Changed from SP3272QN to SP3272QS and now my auto-install program is getting control and no dumps. Still having issues as the auto-install program is not passing any model names.

Tony Thigpen

Tony Thigpen wrote on 8/31/25 9:48 PM:
All,

The problem is actually on z/VSE, but I know there are a lot of VTAM knowledge remaining on this list so I am trying here also. (And, it is a holiday weekend.)

New set of TN3270 terminals and getting some strange errors.

It looks like the local auto-install program never gets control base on EC WTO commands not showing when the error occurs.

 From console:
D6 0432 DFHME0116 PRDCICS
         (Module:DFHMEME) CICS symptom string for message DFHZC5995 is
         PIDS/564805400 LVLS/430 MS/DFHZC5995 RIDS/DFHAPLI1 PTFS/zVSE430
         PRCS/00000145 PRCS/00000010.

 From CICS log:
DFHZC5995 E 08/31/25 19:24:13 PRDCICS CICS logic error. Resource Type Code 145 Subtype 001 not recognized with
            associated bind image


Any thoughts?

Tony Thigpen

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to