Thanks

Joe Reichman


On Wed, Dec 24, 2025 at 9:52 PM James Mulder <[email protected]> wrote:

>    CANCEL abends (X22 completion codes) are not retryable.  The SDWACLUP
> bit will be on in the SDWA.
>
> Jim Mulder
>
> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On Behalf
> Of Joseph Reichman
> Sent: Wednesday, December 24, 2025 9:00 PM
> To: [email protected]
> Subject: RETRY Address not executed on Operator Cancel
>
> I added a TERM= on my ESTAE macro
>
> So that I would intercept operator cancel
>
> My recovery routine got a 222 abend code
>
> However when I did a retry it never hit my retry Routine
>
> Can anybody help ?
>
> Thanks
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to