Happy New Year! (yes, I know it's February already)  I rarely have time for 
IBM-MAIN, but things have changed recently so I plan on poking in now and then 
more often when time permits.  

I can't believe that after all these years these questions still come up.  

The LNKLST supports PDSEs and has since (????) - probably day 1.  Be it 
LNKLSTxx or PROGxx LNKLST or SYSLIB LINKLIB.

PDSE is not allowed in LPALSTxx. This is still documented in z/OS 3.2 - "“You 
cannot use PDSEs in the LPALST concatenation."

Dynamic LPA addition for PDSE is supported after IPL, but doing it in COMMNDxx 
is too early from what I recall since PDSE support relies on other components 
being fully active like, SMS , CATALOG, etc.  Although I admit I haven't looked 
for current doc / recommendations.  I've always done it from a console 
automation software.  

As far as what you can and can't do safely with dynamic LNKLST, read this:
https://www.ibm.com/support/pages/node/879235

It has been out there for a long time and was last updated in January 2025.

Regards,

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS
ITIL v3 Foundation Certified
mailto:[email protected]
Mark's MVS Utilities: http://www.mzelden.com/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,