Most of these answers are "it depends". Can the work be done inline?

MODIFY requires that your work unit be dispatched. Different security
considerations.

SSI 10 should only be issued by command processing which is TCB. If an outlier
issues it to MSTR I would expect an abend. If it is sent specifically to your
application ....

On Sat, 6 Jun 2026 21:14:53 GMT "[email protected]" <[email protected]> wrote:

:>Hello.I have been looking into the use of SSI Function Code 10 - Command 
Processing  -.I can build an SSVT, Invoke IEFSSVT,  I can ACTIVATE the 
subsystem, I can register a command prefix, all the housekeeping is in place 
-..Im looking for guidance, best practices, what to avoid, regarding the actual 
Command Processing program -.Lets start start with the command processing 
program communication with an associated address space -What are the pros/cons 
to using a Space Switching PC routine as opposed to scheduling an SRB intothe 
associated address space ? .When to use a Command Prefix with SSI Function Code 
10 over a traditional MVS Modify command using QEDIT ?.What environment (unit 
of work) is SSI Function code 10 invoked TCB or SRB ?.Is there any additional 
documentation of SSI Function code 10 other than Sub system Interface, that 
discusses developing a command processing program ?.paul  
:>
:>----------------------------------------------------------------------
:>For IBM-MAIN subscribe / signoff / archive access instructions,
:>send email to [email protected] with the message: INFO IBM-MAIN

--
Binyamin Dissen <[email protected]>
http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN