Hi, I am not sure if this is the right list but I’m sure if it’s not then someone will point me in the right direction. I am using the EXIT(OBJECT) to capture records as they are produced. When I don’t specify the GOFF option the records I get are identical to those if written to a file. However, when GOFF is specified the results are quite different. In my case take this simple example:
TEST START TEST AMODE 31 TEST RMODE ANY STM 14,12,12(13) LR 12,15 LHI 15,0 LM 14,12,12(13) BR 14 END When I assemble with GOFF and no exits specified 9 records are produced each prefixed with: 03F00000000000000000000000000000 03000000000000010000000000000000 03000001000000020000000100000000 03000001000000030000000100000000 03000001000000040000000100000000 03000002000000050000000400000000 03100000000000040000000000000000 03100001000000020000000000000000 03400000000000000000000000000000 When I assemble with EXIT(INEXIT…) I get 18 records with very different prefixes: 03F10000000000000000000000000000 03F20000000000000000000000000000 03010000000000010000000000000000 03020000000000000000000000000000 03010001000000020000000100000000 03020000000000000000000000000000 03010001000000030000000100000000 03020000000000000000000000000000 03010001000000040000000100000000 03020000000000000000000000000000 03010002000000050000000400000000 03020000000000000000000000000000 03110000000000040000000000000000 03120000000000000000000000000000 03110001000000020000000000000000 03120000000000000000000000000000 03410000000000000000000000000000 03420000000000000000000000000000 Certainly the binder doesn’t like it: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN: IEW2677S 5130 A VALID ENTRY POINT COULD NOT BE DETERMINED. IEW2230S 0414 MODULE HAS NO TEXT. I have no idea why the assembler output is so different. Neale ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN