Cheers Mainframe’s Finest,
I’m going batty over this or perhaps already have. I have a management class
that works for recent data but fails intermittently at the moment of
performance. About half the datasets lose their backups around day 50.
I have date-derived dataset names that get backups once created but after ~50
days the backups start to disappear. Doing a Listcat ,the problem datasets show
LBAKUP of 0000.000.0000. Listcat also verifies that the datasets all have the
correct classes and storage group. Since the backups disappear, HSM refuses to
delete the expired datasets.
There are no references to the problem datasets in the HSM job logs other than
an occasional PARTREL.
Anyone seen anything like this or have any suggestions on where to look next?
The management class and storage group definitions follow:
Expire after Days Non-usage . : 35
Expire after Date/Days . . . . : 35
Retention Limit . . . . . . . : 35
Partial Release . . . . . . : YES
Migration Attributes
Primary Days Non-usage . : 3
Level 1 Days Date/Days . : 5
Command or Auto Migrate . : COMMAND
Backup Attributes,
Backup frequency . . . . . . . . . . . : 0
Number of backup versions . . . . . . . : 3
(Data Set Exists),
Number of backup versions . . . . . . . : 2
(Data Set Deleted),
Retain days only backup version . . . . : 70
(Data Set Deleted),
Retain days extra backup versions . . . : 35
Admin or User Command Backup . . . . . : BOTH
Auto Backup . . . . . . . . . . . . . . : YES
Backup copy technique . . . . . . . . . : STANDARD
STORAGE GROUP
Auto Migrate . . P
Auto Backup . . Y
Auto Dump . . . N
Overflow . . . . N
Guaranteed Backup Frequency . . . . . . NOLIMIT
David G. Schlecht | Information Technology Professional
State of Nevada | Department of Administration | Enterprise IT Services
T:(775)684-4328 | F: (775) 684‐4324 | E:[email protected]
________________________________
This communication, including any attachments, may contain confidential
information and is intended only for the individual or entity to which it is
addressed. Any review, dissemination or copying of this communication by anyone
other than the intended recipient is strictly prohibited. If you are not the
intended recipient, please contact the sender by reply e-mail and delete all
copies of the original message.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN