>We are installing a Zec12 and trying to IPL our test systems.
>We do not have the STP configured yet, but we are just trying to ipl the
sysplex.
>We are getting the message IXC434I:
>
>IXC434I SYSTEM SYSC HAS TIMING DEFINITIONS THAT ARE NOT
>        CONSISTENT WITH THE OTHER ACTIVE SYSTEMS IN SYSPLEX SCCTEST
>        - EFFECTIVE CLOCK VALUES ARE NOT CONSISTENT.
>               SYSTEM: SYSC  IS USING LOCAL
>               SYSTEM: SYSC  IS USING EDCITS
>
>How does it even know about EDCITS?  Why can't we ipl using the local
time?

XCF has detected that the sysplex couple dataset has an old entry in the
SMST for
SYSC running in STP-only CTN EDCITS.

Are you saying CLOCKxx specified ETRMODE NO, STPMODE NO?
Do you specify SIMETRID? What do you specify for PLEXCFG in IEASYSxx?

I am guessing that you specified SIMETRID as you talk about ipling the
sysplex.
In that case you should reply I to IXC420D to intialize the sysplex.

If you did not specify SIMETRID then it seems you have specified
PLEXCFG=MULTISYSTEM
or ANY. You need to specify PLEXCFG=XCFLOCAL.

George Kozakos
z/OS Software Service, Level 2 Supervisor

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to