> The command output shows INTERNAL. Are you issuing the command from the > internal reader or thru some strange product? Is there an automation product > that is suppressing the original command and re-issuing it with the options?
The command was issued from STC09092, which he said is control-O. My guess is that the command was issued using some CONTROL-O interface (that I don't know), which in turn is using MGCRE *without* an explicitly defined EMCS console and instead using console id 0 which translates to INTERNAL. And Control-O apparently doesn't get the responses to a command and displays them properly. The question is if the operators can see the command response when they use a true console and issue the command directly. Barbara ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN