Thanks Peter and Richard:

 Finally we've customized this IEASYMxx member:

SYSDEF HWNAME(P007ED2A)                   /* CPC MAJADAHONDA */              
|-------> Main site
       SYMDEF(&HWNAME='ED2A')         /* CPU HARDWARE NAME */               |
       SYMDEF(&SITE='&HWNAME(-2:2)')    /* MEMBERS MAJADAHONDA */      |
       SYSNAME(VSIS)                                                            
                           | 
/**************************************************************************/
SYSDEF HWNAME(P00507B7)                   /* CPC ALCALA */            
|--------> disaster recover site         
       SYMDEF(&HWNAME='07B7')         /* CPU HARDWARE NAME */  |
       SYMDEF(&SITE='&HWNAME(-2:2)')    /* MEMBERS ALCALA */    |
       SYSNAME(VSIS)                                                            
             |

And it works fine.

We dont' ask formally a request for this. This way is right for us. 

Regards

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to