Thanks Peter and Richard:
Finally we've customized this IEASYMxx member:
SYSDEF HWNAME(P007ED2A) /* CPC MAJADAHONDA */
|-------> Main site
SYMDEF(&HWNAME='ED2A') /* CPU HARDWARE NAME */ |
SYMDEF(&SITE='&HWNAME(-2:2)') /* MEMBERS MAJADAHONDA */ |
SYSNAME(VSIS)
|
/**************************************************************************/
SYSDEF HWNAME(P00507B7) /* CPC ALCALA */
|--------> disaster recover site
SYMDEF(&HWNAME='07B7') /* CPU HARDWARE NAME */ |
SYMDEF(&SITE='&HWNAME(-2:2)') /* MEMBERS ALCALA */ |
SYSNAME(VSIS)
|
And it works fine.
We dont' ask formally a request for this. This way is right for us.
Regards
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN