Yes, it is very difficult to lower CDS parameters. But why would you do so? The value only designates the maximum for which the CDS is formatted and does not cost anything, except a few tracks of space maybe. It is probably not worth the effort to reclaim these tracks.
Kees. -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Jorge Garcia Sent: Tuesday, November 05, 2013 11:13 To: [email protected] Subject: Format CFRM couple dataset Hello group: Our actual CFRM CDS is formated with ITEM NAME(CF) NUMBER(2). This isn't the actual situacion and we want update the dataset with ITEM NAME(CF) NUMBER(1). Our CFRM policy is updated with one CF but when we want to add the new CFRM CDS the sysplex reject with: IXC255I UNABLE TO USE DATA SET 296 SYS1.SYSPLEX0.CFRM.CDS01 AS THE ALTERNATE FOR CFRM: ALLOWABLE SIZE OF IXCLOADP RECORDS IS LESS THAN CURRENT PRIMARY RELEVANT CFRM COUPLE DATA SET FORMAT INFORMATION PRIMARY FORMAT KEYWORDS: POLICY(6) CF(3) STR(50) CONNECT(32) SMREBLD(1) SMDUPLEX(1) MSGBASED(1) ALTERNATE FORMAT KEYWORDS: POLICY(6) CF(1) STR(50) CONNECT(32) SMREBLD(1) SMDUPLEX(1) MSGBASED(1) Is it necessary a sysplex wide ipl for change this item? Regards Jorge Garcia Juanino Gestor de servicio sistemas z/OS DGTP – DIAC – Area servicios de CPD MAPFRE C/ Orduña, 1 (2º Planta) 28034 Madrid Tfno.: 91 581 27 34 – Extension interna: 412734 Movil: 618333559 [email protected] ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ******************************************************** For information, services and offers, please visit our web site: http://www.klm.com. This e-mail and any attachment may contain confidential and privileged material intended for the addressee only. If you are not the addressee, you are notified that no part of the e-mail or any attachment may be disclosed, copied or distributed, and that any other action related to this e-mail or attachment is strictly prohibited, and may be unlawful. If you have received this e-mail by error, please notify the sender immediately by return e-mail, and delete this message. Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or its employees shall not be liable for the incorrect or incomplete transmission of this e-mail or any attachments, nor responsible for any delay in receipt. Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal Dutch Airlines) is registered in Amstelveen, The Netherlands, with registered number 33014286 ******************************************************** ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN