Also, check to see if you have anything in your ISPF Allocation that might be pre-empting your vendor functions.
Use TSO ISRDDN to review your current session allocations. Also see if you can identify the REXX/CLIST/Command that is being used. Then use M name-of-rexx/clist/command in the COMMAND Line. There might be a same named member that is getting into the way. Lizette > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Lizette Koehler > Sent: Friday, January 03, 2014 5:50 PM > To: [email protected] > Subject: Re: Vendor task failing to populate ISPF.SPFTEMP0.CNTL > > Also, Does this member have details in it? > > > Source Dsname,===>,'SYSP.CW.MLXT930.SLXTSAMP(TRIMAIN)' > > Lizette > > > > -----Original Message----- > > From: IBM Mainframe Discussion List [mailto:[email protected]] > > On Behalf Of Lizette Koehler > > Sent: Friday, January 03, 2014 5:47 PM > > To: [email protected] > > Subject: Re: Vendor task failing to populate ISPF.SPFTEMP0.CNTL > > > > A couple of questions. > > > > 1) Any maintenance applied to the vendor product? > > 2) Any changes to the ISPF environment? > > 3) When was the last time it was successfully used? Is it the same > > LPAR > where you > > are working from now? > > > > I like ISPVCALL for diagnosing the ISPF environment. > > > > Type in TSO ISPVCALL, run the application, then TSO ISPVCALL after it > > completes. > > > > You will have a very large file to browse, but should have sufficient > details for the > > VENDOR. > > > > Lizette > > > > > > > -----Original Message----- > > > From: IBM Mainframe Discussion List > > > [mailto:[email protected]] On Behalf Of John Norgauer > > > Sent: Friday, January 03, 2014 3:46 PM > > > To: [email protected] > > > Subject: Vendor task failing to populate ISPF.SPFTEMP0.CNTL > > > > > > A vendor software task fails to insert JCL's into my SPFTEMP0.CNTL > > dataset. I get > > > the message: > > > > > > IKJ56265I THE DATA SET IS EMPTY. > > > > > > The vendor says that there is an ISPF problem but I am not sure > > > about > > this. > > > > > > Anyone have an idea on why this message is occuring? > > > > > > Thanks. > > > > > > > > > > > > John Norgauer > > > Senior Systems Programmer > > > Mainframe Technical Support Services University of California Davis > > > Medical Center > > > 1651 Alhambra Blvd > > > Suite 200 > > > Sacramento, Ca 95816 > > > 916-734-0536 > > > > > > SYSTEMS PROGRAMMING...... Guilty, until proven innocent !! " JN > 2004 > > > ........ > > > "Hardware eventually breaks - Software eventually works" anon > > > ........ > > > > > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN