On the subject of the size of the TIOT, I am aware of
conversations between MXG customers and IBM development
and I believe there will be a counter added to the SMF 30
record with the count of TIOT entries, so that we can
identify those steps approaching the physical limit.


Barry


Herbert W. "Barry" Merrill, PhD
President-Programmer
MXG Software
Merrill Consultants
10717 Cromwell Drive
Dallas, TX 75229
[email protected]

http://www.mxg.com - FAQ has Most Answers 
[email protected]      - invoices/PO/Payment
[email protected]    - technical
tel: 214 351 1966  - expect slow reply, use email 
fax: 214 350 3694  - prefer email, still works



-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Blaicher, Christopher Y.
Sent: Wednesday, February 05, 2014 10:39 AM
To: [email protected]
Subject: Re: Number of entries in the TIOT

The end of the list is shown by having a TIOELNGH of zero.  Also, TIOSLTYP bit 
will be on if the entry has been freed.  You can skip the entry if this is on.  
You only have to worry about that bit if you do dynamic allocation and free 
data sets as your program runs.

Chris Blaicher
Principal Software Engineer, Software Development Syncsort Incorporated
50 Tice Boulevard, Woodcliff Lake, NJ 07677
P: 201-930-8260  |  M: 512-627-3803
E: [email protected]


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of MichealButz
Sent: Wednesday, February 05, 2014 11:16 AM
To: [email protected]
Subject: Number of entries in the TIOT

When scanning the TIOT IS there and end marker,  how do I know I have scanned 
all the DDnames ?



Thanks


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

________________________________



ATTENTION: -----

The information contained in this message (including any files transmitted with 
this message) may contain proprietary, trade secret or other confidential 
and/or legally privileged information. Any pricing information contained in 
this message or in any files transmitted with this message is always 
confidential and cannot be shared with any third parties without prior written 
approval from Syncsort. This message is intended to be read only by the 
individual or entity to whom it is addressed or by their designee. If the 
reader of this message is not the intended recipient, you are on notice that 
any use, disclosure, copying or distribution of this message, in any form, is 
strictly prohibited. If you have received this message in error, please 
immediately notify the sender and/or Syncsort and destroy all copies of this 
message in your possession, custody or control.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to