It's not just VSAM.
SMS datasets use the VVDS, as well.
-
Ted MacNEIL
eamacn...@yahoo.ca
Twitter: @TedMacNEIL

-----Original Message-----
From:         Doug Fuerst <d...@bkassociates.net>
Sender:       IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU>
Date:         Thu, 6 Feb 2014 18:25:43 
To: <IBM-MAIN@LISTSERV.UA.EDU>
Reply-To:     IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU>
Subject: Re: Implicit VVDS creation

You have that many VSAM datsets on a volume?
10 tracks holds a fair amount of data for a VVDS.

Doug

Doug Fuerst
BK Associates
718.921.2620
917.572.7364
d...@bkassociates.net



------ Original Message ------
From: "David G. Schlecht" <dschle...@admin.nv.gov>
To: IBM-MAIN@listserv.ua.edu
Sent: 2/6/2014 12:55:12 PM
Subject: Re: Implicit VVDS creation

>Hold the presses! The documents for v1r13 say the VVDSSIZE defaults to 
>TRKS(10 10). Holy cow, that's a whole lot less than 10 cylinders.
>
>One would think that at 10 tracks, the VVDS would run out of space (and 
>extents) quite frequently but I don't see this being a frequent topic 
>on IBM-MAIN.
>
>
>  snip>>>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to