I agree 100% but here is our problem: "What's the difference between obsolete hardware and obsolete software?" Obsolete hardware is in a museum - Obsolete software is in production running your business.
-----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of R.S. Sent: Tuesday, February 11, 2014 3:38 PM To: [email protected] Subject: Re: Large Multi-Volume Physical Sequential allocation question W dniu 2014-02-11 19:18, Cosby, Bob - OCFO pisze: > > Question 3: Any reason not to use an SMS pool? Yes; we are a Payroll > Processing center that pays 660,000 Federal Employees utilizing Computer > Associates > IDMS. A lot of the code was written in the 1970's and > 1980's; more importantly a lot of the batch processes that are used > Un-catalogs DSNs which my understanding in SMS un-catalogs > does a delete which the programmer could not go back to a previous step where > a DSN was un-cataloged re-catalog the DSN and start processing > from that step. That's the root reason why you have p roblems with quite elementary things. I don't criticize you, but I criticize the shop. You missed at least 20 year of improvements. SMS is 30 years old, catalog much more. BTW: I use code (partially) written in 1970's, but it's under current mainenance, it works with z/OS 1.13, DB2 (younger than the code!), and other really current features. Regards -- Radoslaw Skorupka Lodz, Poland -- Treść tej wiadomości może zawierać informacje prawnie chronione Banku przeznaczone wyłącznie do użytku służbowego adresata. Odbiorcą może być jedynie jej adresat z wyłączeniem dostępu osób trzecich. Jeżeli nie jesteś adresatem niniejszej wiadomości lub pracownikiem upoważnionym do jej przekazania adresatowi, informujemy, że jej rozpowszechnianie, kopiowanie, rozprowadzanie lub inne działanie o podobnym charakterze jest prawnie zabronione i może być karalne. Jeżeli otrzymałeś tę wiadomość omyłkowo, prosimy niezwłocznie zawiadomić nadawcę wysyłając odpowiedź oraz trwale usunąć tę wiadomość włączając w to wszelkie jej kopie wydrukowane lub zapisane na dysku. This e-mail may contain legally privileged information of the Bank and is intended solely for business use of the addressee. This e-mail may only be received by the addressee and may not be disclosed to any third parties. If you are not the intended addressee of this e-mail or the employee authorized to forward it to the addressee, be advised that any dissemination, copying, distribution or any other similar activity is legally prohibited and may be punishable. If you received this e-mail by mistake please advise the sender immediately by using the reply facility in your e-mail software and delete permanently this e-mail including any copies of it either printed or saved to hard drive. mBank S.A. z siedzibą w Warszawie, ul. Senatorska 18, 00-950 Warszawa, www.mBank.pl, e-mail: [email protected] Sąd Rejonowy dla m. st. Warszawy XII Wydział Gospodarczy Krajowego Rejestru Sądowego, nr rejestru przedsiębiorców KRS 0000025237, NIP: 526-021-50-88. Według stanu na dzień 01.01.2014 r. kapitał zakładowy mBanku S.A. (w całości wpłacony) wynosi 168.696.052 złote. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN This electronic message contains information generated by the USDA solely for the intended recipients. Any unauthorized interception of this message or the use or disclosure of the information it contains may violate the law and subject the violator to civil or criminal penalties. If you believe you have received this message in error, please notify the sender and delete the email immediately. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN