Agreed that this may not be sufficient to ride out a power outage. I can't test it because we never power off. Try it. If the problem persists, OP might open an SR with IBM. Otherwise try to 'automate' RRS cold start for the first IPL of the week. Cold start involves deleting/reallocating one structure and starting RRS. When the newly allocated structure is encountered, RRS performs cold start processing. There has never been a PARM or command to induce RRS cold start. . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 626-302-7535 Office 323-715-0595 Mobile [email protected]
From: Mark Jacobs <[email protected]> To: [email protected], Date: 02/20/2014 08:33 AM Subject: Re: Machine power off and CF Sent by: IBM Mainframe Discussion List <[email protected]> I'm not sure about that answer, you might have to perform an RRS cold start. Mark Jacobs On 02/20/14 10:35, Skip Robinson wrote: > When you power off a CF (internal or external) you lose all allocated > structures. Most exploiters, unless they have been shut down squeaky > clean--expect to find residual data in the CF from their previous active > state. Like most applications, RRS should be OK to start afresh on Monday > morning if it came down gracefully, > > . > . > J.O.Skip Robinson > Southern California Edison Company > Electric Dragon Team Paddler > SHARE MVS Program Co-Manager > 626-302-7535 Office > 323-715-0595 Mobile > [email protected] > > > > From: "Mullen, Patrick" <[email protected]> > To: [email protected], > Date: 02/20/2014 07:12 AM > Subject: Re: Machine power off and CF > Sent by: IBM Mainframe Discussion List <[email protected]> > > > > SETRRS SHUTDOWN has always worked fine for us. > > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Miklos Szigetvari > Sent: Thursday, February 20, 2014 6:29 AM > To: [email protected] > Subject: Machine power off and CF > > > Hi > > We have to power off our z9 for the weekends, and we are experiencing > > problems with the > RRS log structures after the restart . > Any important shutdown command we need to issue to avoid this ? > (SETRRS SHUTDOWN ? ) > > -- > Kind regards, / Mit freundlichen Grüßen > Miklos Szigetvari ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN