What hardware are you using SSD in? IBM DS8??? EMC VMAX or DMX HDS
If you have a VMAX 40K then the product FAST VP probably will replace the need for you to tune the SSD in HSM. If you have a DS8870 then Protect Tier or Fast Tier may replace the need to manage the SSD. The Hardware Storage Arrays are now taking over moving data that is "hot" to faster devices without HSM or the user knowing it is occurring. Lizette > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of R.S. > Sent: Thursday, March 06, 2014 7:11 AM > To: [email protected] > Subject: Re: SSD in DFSMS > > W dniu 2014-03-06 08:45, Vernooij, CP (SPLXM) - KLM pisze: > > I remembered having heard or read this and the first Google hit was: > > http://pic.dhe.ibm.com/infocenter/zos/v1r12/index.jsp?topic=%2Fcom.ibm > > .zos.r12.idas200%2Fs2082.htm > > Is this what you are looking for? > Well, yes and no. > Yes, this is some (the only?) documentation which covers SSD support in DFSMS. > No - it lacks of recommendation, discussion, samples, etc. > > BTW: Don't you think the table documents fiction? This is from z/OS 1.12, quite up > to date. However the table covers ancient devices, AFAIK the oldest one is from > 1975. How can I connect it? How can I use the information? > Not to mention, that even 2105 or 2107 could mean completely different devices > from performance point of view. There is completely no wise reason to assume that > 2105 has given performance characteristics. > > -- > Radoslaw Skorupka > Lodz, Poland > > P.S. Thank you for pointing that! > > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN