It is a non IMS SVC. I found this program which worked prefectly. http://www.rizzuto.it/tools/svcupdte.txt
Jim McAlpine On Thu, Mar 13, 2014 at 1:33 PM, Lizette Koehler <[email protected]>wrote: > Is the type 4 for any product or IMS? > > IMS Has a dynamic SVC process you can use. > > Lizette > > > > -----Original Message----- > > From: IBM Mainframe Discussion List [mailto:[email protected]] On > > Behalf Of Jim McAlpine > > Sent: Thursday, March 13, 2014 2:52 AM > > To: [email protected] > > Subject: adding a type 4 SVC > > > > It's a long, long time since I had to do the above and I presume things > have changed > > some since then. So the question is, can I dynamically add a type 4 SVC > to a z/OS > > 1.13 system or is an IPL still needed ? > > > > Jim McAlpine > > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN