> -----Original Message-----
> From: IBM Mainframe Discussion List On Behalf Of Hank Oerlemans
>
> The behavior can be demonstrated with the PDS utility and leaving off the SHR
> parameter when
> specifying COMPRESS.
>
>
> Don't blame ISPF. The critical thing is DISP=OLD allocation occurring
> after a DISP=SHR.
Right; that part we understand. We've also learned from our scheduler vendor
that it attempts to obtain exclusive control of the library MEMBER, rather than
the whole library, at job submission time. We're still trying to figure out
how one user was able to allocate that library with DISP=OLD. Never observed
here before; might never happen again.
-jc-
**********************************************************************
Information contained in this e-mail message and in any attachments thereto is
confidential. If you are not the intended recipient, please destroy this
message, delete any copies held on your systems, notify the sender immediately,
and refrain from using or disclosing all or any part of its content to any
other person.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN