At 19:18 +0000 on 04/12/2014, [email protected] wrote about Tesing A
SubSystem Initialization Routine:
Im Trying to set up and test a SubSystem Initialization Routine.
While I am testing I would like to be able to rerun the routine for
this subsystem ID without IPLING, in the event it abends.
(And we all have abended)
I have been able to add & Remove My SubSystem Initialization Routine
in LPA by using CSVDYLPA.
I can use either SETSSI command or the IEFSSI ADD function to add
the subsyetm.
Now I would like to Add a subsystem dynamically via SETSSI command
or IEFSSI macro and identify a subsystem Initialization routine to
run.
.
If the Initialization Routine Abends, How do I re-run it again
without an IPL ?
My understanding is that If I Try To add an existing Subsustem a
second time, it would fail. If my Initialization routine fails
during Testing, How do I re-run it again to test it without an IPL ?
.
Any Recommendations, suggestions ?
I assume the re-run issue is that the location where the routine
resides is locked in when you first define the Sub-System and thus
can not be replaced with a new copy (which will be somewhere else in
memory). Why not make the routine have a static location and be
composed of a LOAD of the real routine? That way it would be able to
locate a new copy that was handled by the CSVDLYPA routine.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN