Funny, I was just looking at that.

Thanks. I am real aware of SYS(EXITS()) versus SUBSYS(XXX,EXITS()). 

My product now warns if it is told to monitor subsystem XXX but 
SUBSYS(XXX,EXITS(IEFU83/4/5)) has not been specified. But it does not "know" if 
there is also a subsystem YYY that it has not been told about.

Looking at SHOWZOS I can see how to do it from SMCA->SST, but as you said, GUPI 
it ain't.

Charles

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Rob Scott
Sent: Friday, April 25, 2014 5:04 AM
To: [email protected]
Subject: Re: Any way to programmatically determine state of SMFPRMxx 
SYS(EXITS())?

Charles

Finding out which SMF subsystems are defined in SMFPRMxx is also something to 
consider as SYS.IEFU83 and SYSxxxx.IEFU83 can point to different module lists 
and your software may have to install its exit to every SMF subsystem.

I am surprised that IFAQUERY has not been enhanced to return extra SMF related 
information like this. 

Rob Scott
Lead Developer
Rocket Software
77 Fourth Avenue . Suite 100 . Waltham . MA 02451-1468 . USA
Tel: +1.781.684.2305
Email: [email protected]
Web: www.rocketsoftware.com

----------------------------------------------------------------------